植物配置对水体扑草净去除效果研究

Study on Removal Effects of Plant Configurations on Prometryn in Water

  • 摘要: 采用温室水培模拟试验,研究不同浓度扑草净污染下,香根草、菖蒲及其2∶1配置于水体中第0、6、12、24、30 天扑草净含量。结果表明:不同浓度扑草净污染水体中,培育植物条件下第30 天扑草净去除率为58.60%~91.69%,CK扑草净去除率为45.86%~57.48%,培育植物组显著高于CK。当扑草净初始浓度<4 mg/L时,香根草对水体扑草净污染的去除效率最高,第30 天达到88.4%;扑草净初始浓度≥4 mg/L时,香根草、菖蒲生物量2∶1组合对水体扑草净污染的去除效率最高,第30天达到91.69%。研究结果可为不同浓度扑草净污染水体植物修复提供参考。

     

    Abstract: A greenhouse hydroponic simulation experiment was conducted to study the prometryn content in water at 0, 6, 12, 24, and 30 days under different concentrations of prometryn pollution in Vetiveria zizanioides, Acorus calamus, and their 2∶1 configuration. The findings revealed that in water polluted by different concentrations of prometryn, the removal rate of prometryn in the plant planting group was 58.60%–91.69% on the 30th day, while in the control group (without planting plants), the removal rate of prometryn was 45.86%–57.48% on the 30th day. The plant planting group was significantly higher than the control group. When the initial concentration of prometryn was <4 mg·L−1, the removal efficiency of V. zizanioides(V) for prometryn pollution in water was the highest, reaching 88.4% on the 30th day. When the initial concentration of prometryn was ≥ 4 mg· L−1, the 2∶1 combination of V. zizanioides and A. calamus(2V-1A) had the highest removal efficiency of prometryn pollution in water, reaching 91.69% on the 30th day. This study provided references for phytoremediation of water bodies polluted by prometryn at different concentrations.

     

/